Home > Products > Protectors > Industrial Canisters
 
Industrial Canister Type 1L
Color Green with white stripe
Protection type All-purpose protection
Protection against (example) Hydrocyanic acid cyanogens chloridearsine, phosgenechloropicrin, benzenebromomethane ,lewisite gastoxic smoke and fume hydrogen phosphate , etc.
Smoke filter yes

Test Agent: HCN
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)

11.2(1.0)

80
Medium canister (MP)
5.6(0.5)
40
Small canister (MQ)
3.4(0.3)
20

Test Agent: CNCI
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
6.0
70
Medium canister (MP)
3.0
40
Small canister (MQ)
1.5
20

Industrial Canister Type 1
Color Green
Protection type All-purpose protection
Protection against (example) Hydrocyanic acid cyanogens chloride arsine, chloropicrin phosgene, benzene, bromomethane, lewisite gas, hydrogen phosphate ,etc.
Smoke filter no

Test Agent: HCN
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
5.6(6.0)
70

Test Agent: CNCI
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
3
55

Industrial Canister Type 2L
Color Orange red with white stripe
Protection type All-purpose protection(incl.CO)
Protection against (example) Carbon monoxide, organic vapors,hydrocyanic acid and its derivatives,toxic smoke and fume, etc.
Smoke filter yes

Test Agent: HCN
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
5.6(0.5)
120

Test Agent: CO
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
5.8(0.5)
150
Small canister (MQ)
5.8(0.5)
20

Industrial Canister Type 3L
Color Brown with white stripe
Protection type Against organic gases
Protection against (example) benzene, chlorine, acetone, alcohols,anilines, carbon disulfide,carbon tetrachloride,chloroform, bromomethane,chloromethane,nitroalkanes,toxic smoke and fume, etc.
Smoke filter yes

Test Agent: benzene
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
32.5(1.0)
120

Test Agent: chlorine
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
29.6(1.0)
60

Industrial Canister Type 3
Color Brown
Protection type Against organic gases
Protection against (example) benzene, chlorine, acetone, alcohols,anilines,carbon disulfide,carbon tetrachloride,chloroform, bromomethane,chloromethane,nitroalkanes, etc.
Smoke filter no

Test Agent: benzene
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
16.2(0.5)
130
Small canister (MQ)
9.7(0.3)
70

Test Agent: chlorine
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
14.8(0.5)
55
Small canister (MQ)
8.8(0.3)
20

Industrial Canister Type 4L
Color Grey with white stripe
Protection type Against ammonia and hydrogen sulfide
Protection against (example) Ammonia hydrogen sulfide,toxic smoke and fume
Smoke filter yes

Test Agent: ammonia
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
7.1(1.0)
50

Test Agent: sulfureted hydrogen
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
14.1(1.0)
55

Industrial Canister Type 4
Color Grey
Protection type Against ammonia and hydrogen sulfide
Protection against (example) Ammonia and hydrogen sulfide
Smoke filter no

Test Agent: ammonia
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
3.6(0.5)
60
Small canister (MQ)
2.1(0.3)
25

Test Agent: sulfureted hydrogen
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
7.1(0.5)
95
Small canister (MQ)
4.2(0.3)
25
Industrial Canister Type 5
Color White
Protection type Against carbon monoxide
Protection against (example) Carbon monoxide
Smoke filter no

Test Agent: CO
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
5.8(0.5)
110

Industrial Canister Type 6
Color Black
Protection type Against
Protection against (example) Mercury vapor
Smoke filter yes

Test Agent: Hg
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
0.01(0.00012)
4800

Industrial Canister Type 7L
Color Yellow with white stripe
Protection type Against acid gases
Protection against (example) Sulfur dioxide, chlorine, phosgene,hydrogen sulfide,nitrogen oxides,phosphorus and chlorine-containing organic pesticides,toxic smoke and fume, etc.
Smoke filter yes

Test Agent: NO2
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
19.1(1.0)
30

Test Agent: sulfur dioxide
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
26.6(1.0)
30
Industrial Canister Type 7
Color Yellow
Protection type Against acid gases
Protection against (example) Sulfur dioxide, chlorine, hydrogen sulfide,nitrogen oxides,phosgene, phosphorus and chlorine-containing organic pesticides
Smoke filter no

Test Agent: sulfur dioxide
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Medium canister (MP)
13.3(0.5)
32
Small canister (MQ)
8(0.3)
20

Industrial Canister Type 8L
Color Blue with white stripe
Protection type Against hydrogen sulfide
Protection against (example) Hydrogen sulfide toxic smoke and fume
Smoke filter yes

Test Agent: sulfureted hydrogen
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
14.1(1.0)
65
Medium canister (MP)
7.1(0.5)
100
Small canister (MQ)
4.2(0.3)
30

Industrial Canister Type 8
Color Blue
Protection type Against hydrogen sulfide
Protection against (example) Hydrogen sulfide
Smoke filter no

Test Agent: sulfureted hydrogen
Type
Test concentration mg/L
(volume concentration%)
Minimum service life
(min)
Large canister (MD)
14.1(1.0)
85
Medium canister (MP)
7.1(0.5)
120
Small canister (MQ)
4.2(0.3)
40

 