Home
> Products
> Welding Products > Special Machines > NDT X-Ray Equipment >
Portable X-Ray Equipment |
NDT Portable X-Ray Equipment
|
|
|

Introduction of Frequency Conversion Gas Insulated Portable NDT X-Ray Equipment
Compact x-ray generator, anode grounded, forced air cooling
Light weight, portable, easy to use
The ratio of the exposure tine to the stop time is 1:1
Aging the x-ray generator and checking the exposure parameter automatically
High-voltage time-delay function protects the operator from radiation
Strictly controlled production technique, nice outward, reasonable design
|
|
|
Directional Portable NDT X-Ray Equipment (with glass x-ray tube)
XXQ-1005, XXQ-1605 are suitable for the testing of the steel plate, aluminum, rubber, etc. The image quality and the resolution are both excellent.
Model |
XXQ-1005 |
XXQ-1605 |
XXQ-2005 |
XXQ-2505 |
XXQ-3005 |
Output Voltage(kV) |
20-100 |
40-160 |
100-200 |
150-250 |
170-300 |
Input(kW) |
1.2 |
1.5 |
2.0 |
2.5 |
3.0 |
Focus Spot(mm) |
0.8X0.8 |
0.8X0.8 |
1.5X1.5 |
2.0X2.0 |
2.3X2.3 |
Beam Angle |
40° |
40° |
40+5° |
40+5° |
40+5° |
Max. Penetration(mm) |
8 |
18 |
30 |
40 |
50 |
Weight of Generator(kg) |
8.5 |
16 |
20 |
37 |
44 |
Weight of Controller(kg) |
10 |
10 |
13.5 |
19.5 |
21.5 |
Dimensions of Generator(mm) |
Ø135X555 |
Ø195X610 |
Ø275X665 |
320X320X730 |
340X340X830 |
Dimensions of Controller(mm) |
280X280X170 |
280X280X170 |
365X280X170 |
365X310X225 |
365X310X225 |
|
|
 |
Directional Portable NDT X-Ray Equipment XXQ-1605 (with glass x-ray tube) |
|
Panoramic Portable NDT X-Ray Equipment (with glass x-ray tube)
XXH-1005, XXH-1605 are suitable for the testing of small diameter pipe welding. Installing wheels or pipe line crawler (the controller could be put into pipe together with the generator) on it, may perform the round welding exposure in one time.
Model |
XXH-1005 |
XXH-1605 |
XXH-2005 |
XXH-2505 |
XXH-3005 |
Output Voltage(kV) |
20-100 |
40-160 |
100-200 |
150-250 |
170-300 |
Input(kW) |
1.2 |
1.5 |
2.0 |
2.5 |
3.0 |
Focus Spot(mm) |
1.0X3.5 |
1.0X3.5 |
1.0X3.5 |
1.0X2.4 |
1.0X2.3 |
Beam Angle for Cone Target |
30+5° |
30+5° |
30+5° |
30+5° |
30+5° |
Beam Angle for Level Target |
25+5° |
25+5° |
25+5° |
25+5° |
25+5° |
Max. Penetration(mm) |
8 |
18 |
30 |
40 |
50 |
Weight of Generator(kg) |
8.5 |
10.5 |
20 |
37 |
44 |
Weight of Controller(kg) |
10 |
10 |
13.5 |
19.5 |
21.5 |
Dimensions of Generator(mm) |
Ø135X555 |
Ø135X685 |
Ø275X665 |
320X320X730 |
340X340X830 |
Dimensions of Controller(mm) |
280X280X170 |
280X280X170 |
365X280X170 |
365X310X225 |
365X310X225 |
|
|
 |
Panoramic Portable NDT X-Ray Equipment XXQ-2505 (with glass x-ray tube) |
|
Intelligent Controller Model T4886
Choosing the microprocessing system of high performance and the modulized components reached the higher automation.
The film front panel with dust-proof and the water-proof functions displays with LCD and operates with man-machine dialogue.
Advanced anti-interference design makes the controller suitable for the hard operation environment.
The keyboard and the high voltage could be locked to prevent a wrong operation. High voltage time-delay function helps the operator leaving the radiative site in time.
Automatic memory function can record the off-duty time of the equipment and can do the aging of the equipment automatically.
Compact design, light weight and sturdy.
Dimensions of the controller: 150mmX280mmX366mm
Weight of the controller: 10kgs.
|
|
 |
Intelligent Controller Model T4886 |
|